Free Shipping on Parts & Accessories | Ships Within 2 Business Days
$0.00 0

Cart

No products in the cart.

Continue shopping

Williams 9A333 High Altitude Orifice Kit (2,001-8,000 ft) for Monterey 5009622A Natural Gas

$35.99

High altitude orifice kit for Monterey 50,000 BTU natural gas top vent wall furnaces (5009622A / 5009822), for installations from 2,001 to 8,000 ft. Includes 2 sets of orifices, one for each burner, so one kit covers the whole furnace. Installation by a qualified service technician required.

SHIPS WITHIN 2 business days

Shipping: Free shipping from Colton, CA. Ships within 2 business days. Shipping policy

Returns: Returns accepted within 30 days from delivery if unused and in original packaging. 20% restocking fee applies. You pay return shipping unless the item arrives damaged or defective. Special-order items are final sale. Return policy

SKU: 9A333 Category: Brand:
Model 9A333
Product Type High Altitude Orifice Kit
Elevation Range Covers the full 2,001 – 8,000 ft range
Fits Monterey 5009622A / 5009822 / C505H
Fuel Natural Gas, 50,000 BTU
Kit Contents 6 burner orifices, 2 of each size (one per burner): #44 (2,001 – 4,000 ft), #45 (4,001 – 6,000 ft), #47 (6,001 – 8,000 ft). Install the one listed for your elevation.
Quantity Required 1 kit per furnace (covers both burners of the 50,000 BTU double-sided furnace)
Installation Qualified service technician or gas supplier
Warranty 1 Year Limited
Elevation Input BTU/hr Orifice Size
2,001 – 4,000 ft 50,000 #44 (2 required)
4,001 – 6,000 ft 50,000 #45 (2 required)
6,001 – 8,000 ft 50,000 #47 (2 required)

The kit covers the full 2,001 – 8,000 ft range. Your installer uses the orifice listed for your elevation on both burners.

  • Re-orifices the main burner for installations between 2,001 and 8,000 ft
  • Keeps the burner input correct in thinner air for clean, safe combustion
  • Genuine Williams factory part for Monterey top vent wall furnaces
  • Matched to natural gas models: 5009622A / 5009822

For use with Williams Monterey top vent wall furnaces:

  • 5009622A (50,000 BTU, natural gas)
  • 5009822 (50,000 BTU, natural gas)
  • C505H (50,000 BTU, natural gas)

Note: For natural gas models only. For the propane version of this furnace, use kit 9A336. Furnaces at or below 2,000 ft use the factory orifice and do not need this kit.

  • One kit per furnace. The 50,000 BTU double-sided Monterey has two burners, and this kit includes a full set of orifices for each.
  • Operation above 2,000 ft requires high altitude conversion. The orifice must be installed by a qualified service technician or gas supplier.
  • For elevations above 2,000 ft, reduce the furnace rating 4% for each 1,000 ft above sea level. Never increase input by enlarging the orifice or raising gas pressure.
  • Read the furnace installation manual before installation.
  • Photographs are representative.
Model 9A333
Product Type High Altitude Orifice Kit
Elevation Range Covers the full 2,001 – 8,000 ft range
Fits Monterey 5009622A / 5009822 / C505H
Fuel Natural Gas, 50,000 BTU
Kit Contents 6 burner orifices, 2 of each size (one per burner): #44 (2,001 – 4,000 ft), #45 (4,001 – 6,000 ft), #47 (6,001 – 8,000 ft). Install the one listed for your elevation.
Quantity Required 1 kit per furnace (covers both burners of the 50,000 BTU double-sided furnace)
Installation Qualified service technician or gas supplier
Warranty 1 Year Limited
Elevation Input BTU/hr Orifice Size
2,001 – 4,000 ft 50,000 #44 (2 required)
4,001 – 6,000 ft 50,000 #45 (2 required)
6,001 – 8,000 ft 50,000 #47 (2 required)

The kit covers the full 2,001 – 8,000 ft range. Your installer uses the orifice listed for your elevation on both burners.

  • Re-orifices the main burner for installations between 2,001 and 8,000 ft
  • Keeps the burner input correct in thinner air for clean, safe combustion
  • Genuine Williams factory part for Monterey top vent wall furnaces
  • Matched to natural gas models: 5009622A / 5009822

For use with Williams Monterey top vent wall furnaces:

  • 5009622A (50,000 BTU, natural gas)
  • 5009822 (50,000 BTU, natural gas)
  • C505H (50,000 BTU, natural gas)

Note: For natural gas models only. For the propane version of this furnace, use kit 9A336. Furnaces at or below 2,000 ft use the factory orifice and do not need this kit.

  • One kit per furnace. The 50,000 BTU double-sided Monterey has two burners, and this kit includes a full set of orifices for each.
  • Operation above 2,000 ft requires high altitude conversion. The orifice must be installed by a qualified service technician or gas supplier.
  • For elevations above 2,000 ft, reduce the furnace rating 4% for each 1,000 ft above sea level. Never increase input by enlarging the orifice or raising gas pressure.
  • Read the furnace installation manual before installation.
  • Photographs are representative.

This part is compatible with the following furnace units:

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.